Abstract

Objective: Our purpose was to compare the diagnostic ability and treatment efficacy of conization by the loop electrosurgical excision procedure with cold-knife conization. Study Design: One hundred eighty women who required conization for diagnosis and treatment of cervical dysplasia or microinvasive cervical carcinoma were prospectively enrolled in a randomized clinical trial to receive either cold-knife conization or conization by the loop electrosurgical excision procedure. Conization complications, rate of lesion clearance, and therapeutic outcome were assessed for the 2 study groups. Results: There were no statistically significant differences in the complication rate ( P = 1.00), the rate of lesion clearance ( P = .18), or the rate of disease recurrence ( P = .13) between the 2 study groups. The mean follow-up was 11.2 months in the cold-knife conization group and 10.4 months in the loop-excision conization group. Conclusion: Cold-knife conization and loop-excision conization yield similar diagnostic and therapeutic results. (Am J Obstet Gynecol 1999;180:276-82.)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.