Abstract

The possibility of using a scheme for separate detection of echo signals for obtaining high-quality flaw images is substantiated. A conventional algorithm for obtaining images by the projection method in the spectral space and an algorithm for obtaining images that is not limited by the approximation of a plane incident wave are considered. Coherent storage of images reconstructed from echo signals, which were detected in a separate scheme but at different positions of the radiator (transmitter), reduces the speckle-noise level and increases the resolution of flaw images. Positive and negative features of these algorithms are analyzed. Numerical and model experiments have demonstrated the feasibilities of different schemes of detecting echo signals for obtaining flaw images.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.