Abstract

This paper presents an analysis of personal respirable coal dust measurements recorded by the Joint Coal Board in the underground longwall mines of New South Wales from 1985 to 1999. A description of the longwall mining process is given. In the study, 11 829 measurements from 33 mines were analysed and the results given for each occupation, for seven occupational groups, for individual de-identified mines and for each year of study. The mean respirable coal dust concentration for all jobs was 1.51 mg/m(3) (SD 1.08 mg/m(3)). Only 6.9% of the measurements exceeded the Australian exposure standard of 3 mg/m(3). Published exposure-response relationships were used to predict the prevalence of progressive massive fibrosis and the mean loss of FEV(1), after a working lifetime (40 years) of exposure to the mean observed concentration of 1.5 mg/m(3). Prevalences of 1.3 and 2.9% were predicted, based on data from the UK and the USA, respectively. The mean loss of FEV(1) was estimated to be 73.7 ml.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.