Abstract
Introduction Elevated levels of markers for thrombin activation are associated with plaque echogenicity and degree of stenosis in patients with carotid artery stenosis. The Activated Protein C-Protein C Inhibitor (APC-PCI) complex reflects activation of the Protein C system and is a measure of thrombin generation. The aim of the present study was to examine APC-PCI complex in patients undergoing thrombendartherectomy for carotid artery stenosis, and to relate the findings to clinical characteristics and plaque morphology as determined by ultrasound. Materials and Methods Blood was obtained from 125 patients (39 female, median age 71 years) with carotid artery stenosis admitted from September 2005 to May 2007. The APC-PCI complex was measured using a sandwich immunofluorometric method and compared to an age- and sex-matched healthy control-group. Clinical and demographic characteristics, routine laboratory markers and ultrasound characteristics were analysed using univariate and multivariate analysis. Results APC-PCI complex concentration was significantly increased in patients with carotid artery stenosis (median 0.21 µg/L; 10th to 90th percentile 0.15–0.36) compared to a healthy control-group (0.19 µg/L; 0.11–0.31; P = .009). There was no significant difference in APC-PCI-values between asymptomatic (n = 48) and symptomatic (n = 77) patients with carotid artery stenosis (0.22 vs. 0.20 µg/L; p = 0.626). Patients with minor stroke (n = 31) had a higher median APC-PCI-concentration (0.27 µg/L; 0.15–0.63) than patients with amaurosis fugax (0.19 µg/L; 0.15–0.36) or transient ischemic attack (0.21 µg/L; 0.12–0.36) (p = 0.016). No association was found between APC-PCI-values and the degrees of carotid artery stenosis or the time from the latest neurological symptoms to blood sampling. Patients with echolucent plaques had significantly lower APC-PCI concentrations (0.20 µg/L; 0.14–0.35 vs. 0.24 µg/L; 0.15–0.60; p = 0.043), according to the Gray-Weale classification. Conclusions Patients with carotid artery disease exhibit increased concentrations of APC-PCI compared to a healthy control-group, particularly those patients with echogenic plaques, who have significantly higher APC-PCI levels than patients with echolucent plaques.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Thrombosis Research
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.