Abstract

We present a practical approach for coregistration of bioluminescence tomography (BLT), computed tomography (CT), and magnetic resonance (MR) images. For this, we developed a customized animal shuttle composed of nonfluorescent, MR-compatible Delrin plastic that fits a commercially available MR surface coil. Mouse embryonic stem cells were transfected with the luciferase gene and labeled with superparamagnetic iron oxide nanoparticles. Cells were stereotaxically implanted in the mouse brain and imaged weekly for 4 weeks with bioluminescent imaging (IVIS Spectrum CT scanner) and magnetic resonance imaging (MRI; 11.7 T horizontal bore scanner). Without the use of software coregistration, in vitro phantom studies yielded root-mean-square errors of 7.6 × 10−3, 0.93 mm, and 0.78 mm along the medial–lateral (ML), dorsal–ventral (DV), and anterior–posterior (AP) axes, respectively. Rotation errors were negligible. Software coregistration by translation along the DV and AP axes resulted in consistent agreement between the CT and MR images, without the need for rotation or warping. In vivo coregistered BLT/MRI mouse brain data sets showed a single diffuse region of bioluminescent imaging photon signal and MRI hypointensity. Over time, the transplanted cells formed tumors as histopathologically validated. Disagreement between BLT and MRI tumor location was greatest along the DV axis (1.4 ± 0.2 mm) than along the ML (0.5 ± 0.3 mm) and the AP axes (0.6 mm) because of the uncertainty of the depth of origin of the BLT signal. Combining the high spatial anatomical information of MRI with the cell viability/proliferation data from BLT should facilitate preclinical evaluation of novel therapeutic candidate stem cells.

Highlights

  • Stem cell therapy is a burgeoning area of research for the treatment of a diverse range of diseases

  • We present a protocol for coregistration of reconstructed bioluminescence tomography (BLT) volumes with magnetic resonance imaging (MRI) anatomical data as exemplified by tracking superparamagnetic iron oxide (SPIO)-labeled embryonic stem cells in mouse brain

  • Hematoxylin and eosin staining confirmed the presence of a tumor mass both in the hypointense region and in the area of increased signal intensity seen on MRI

Read more

Summary

Introduction

Stem cell therapy is a burgeoning area of research for the treatment of a diverse range of diseases. In vivo molecular and cellular imaging modalities that are currently used for tracking cells include bioluminescent imaging (BLI) [2,3,4,5], magnetic resonance imaging (MRI) [6,7,8], and magnetic particle imaging (MPI) [9,10,11], and nuclear imaging modalities include single photon emission computed tomography [12,13,14] and positron emission tomography (PET) [15, 16] Each of these techniques has its own advantage and limitation with respect to temporal resolution, anatomical detail, and functional information.

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.