Abstract

A method of CO laser frequency stability measurement is proposed, based on the molecular laser magnetic resonance (LMR) spectrum, which can be used to measure the linewidths of molecular LMR spectra and their changes. The data were treated by the Allan variance method. A series of CO laser frequency stability measurements were obtained from 0.1 s to 1000 s in the time domain. The frequency stability was fitted to a power law function. The expressions of frequency stability were found for a stabilized and a free-running CO laser in the frequency domain.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.