Abstract

Abstract Carbon monoxide and temperature have been measured in the post-flame region of laminar, pre-mixed methane/air flat flames at atmospheric pressure using both laser absorption spectroscopy and conventional probe techniques. The laser absorption measurements employed a tunable diode laser to record fully resolved absorption lines in the fundamental band of CO near 4.7 microns. Probe measurements were made with thermocouples and sampling microprobes (uncooled quartz and water-cooled stainless steel). The extracted gases were analyzed for CO and CO2 using NDIR instruments. The laser absorption measurements of CO in rich flames were in good agreement with chemical equilibrium calculations based on metered fuel and air flow-rates and measured local temperature. In lean flames, measured levels of CO exceeded equilibrium values, as expected, due to incomplete reaction of CO to CO2 near the flame front. Temperatures inferred from the relative absorption in lines from different vibrational levels were in go...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.