Abstract

Endovascular treatment of complex aortic pathology is associated with increases in procedural-related metrics including operative time and radiation exposure. Three-dimensional fusion imaging technology has decreased radiation dose and iodinated contrast use in endovascular aneurysm repair. The aim of this study is to report our institutional experience with use of a cloud-based fusion imaging platform in fenestrated endovascular aneurysm repair (FEVAR). A retrospective review of a prospectively maintained aortic database was performed to identify all patients who underwent commercially-available FEVAR (Zenith Fenestrated, Cook Medical, Bloomington, Ind) between 2013 and 2020, as well as all endovascular aneurysm repairs performed using Cydar EV Intelligent Maps (Cydar Medical, Cambridge, UK). The Cydar EV cohort was reviewed further to select all FEVAR performed with intelligent map guidance. Patient demographics, clinical, and procedural-related metrics were analyzed, with comparative analysis of FEVAR performed without and with the Cydar EV imaging platform. Patients were excluded from the comparative analysis if incomplete in the data set, or if documented history of prior open or endovascular abdominal aortic aneurysm repair. Over the 7-year study period 191 FEVAR were performed. The Cydar EV imaging platform was implemented in 2018 and used in 124 complex endovascular aneurysm repairs, including 69 consecutive FEVAR. A complete dataset was available on 137 FEVAR. With exclusions to select for de novo FEVAR, comparative analysis was performed on 53 FEVAR without and 63 with Cydar EV. Cohorts were similar with respect to patient demographics, medical comorbidities, and aortic aneurysm characteristics. No significant difference was noted between groups on major adverse postoperative events, length of stay, or length of intensive care unit stay. Use of the Cydar EV resulted in nonsignificant decreases in mean fluoroscopy time (69.3 minutes vs 66.2 minutes; P = .598), and a positive trend toward shorter operative times (204.4 minutes vs 186 minutes; P = .278). Notably, a statistically significant decrease in both iodinated contrast volume (104.7 mL vs 83.8 mL; P = .005), and patient radiation exposure via dose-area product (1,049,841 mGy/cm2 vs 630,990; P < .001) was observed in patients undergoing FEVAR with Cydar EV Intelligent Maps. Our aortic center has observed a trend toward shorter operative times, and significant decreased in both iodinated contrast use and radiation exposure during FEVAR with the use of Cydar EV Intelligent Maps. Intelligent map guidance improves the efficiency of complex endovascular aneurysm repair, providing a safer intervention for both patient and practitioner.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.