Abstract
Although most stepped spillway–design guidelines were developed for uniform step heights, a nonuniform stepped design might be a practical alternative in some cases. A physical study was conducted in a moderate slope-stepped chute (1V:2H) and five stepped configurations were tested for 0.7<dc/h<1.9. Detailed air-water flow measurements were performed for each configuration and the results were compared in terms of flow patterns, energy dissipation, and flow resistance. The basic findings showed minor differences between all configurations and indicated that the rate of energy dissipation was about the same for uniform and nonuniform stepped configurations. But the observations suggested that the nonuniform stepped configurations might induce some flow instabilities for smaller flow rates.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.