Abstract

To communicate the experience in an Andean country with the OcclutechTM Duct Occluder device for the closure of patent ductus arteriosus. observational, retrospective, cross-sectional study with basic statistical analysis. Period: December/2014 to December/2022. Data: medical chart, reports of catheterization. Forty-six patients, female 71.3%, male 28.7%; age: 0.6-38 years-old (median [Me]: 5.2); weight: 6.3-60 kg (Me: 16.5). Origin: Andean 91.3%, coast 8.7%. Types of patent ductus arteriosus: E 54.4%, A 32.6%, D 13%. Minimum ductal diameter: 1.8-11.8 mm (Me: 3.5). Mean pulmonary artery pressure prior to occlusion: 14-67 mmHg (Me: 27). Pulmonary vascular resistance index prior to occlusion: 0.28-4.9 WU/m2 (Me: 1.3). Six of them were classified as hypertensive patent ductus arteriosus. Occlusion rate: 47.8% immediate, 81% at 24 hours, 100% after six months. Fluoroscopy time: 2-13.8 minutes (Me: 4). Complications: a migrated device. Follow-up: 1-6.5 years. OcclutechTM Duct Occluder device was effective and safe for the closure of patent ductus arteriosus type E, A and D in low-altitude and high-altitude dwellers, whether they were children or adults, even when these ductus arteriosus were hypertensive.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call