Abstract
Closed orbit deviations of the main ring of KEK-PS are corrected at injection by supplying individual currents to 56 steering dipoles placed downstream of quadrupole magnets. Half of them are used for the correction of the horizontal orbit and the rest for the vertical orbit. Correction is made by making a local closed orbit with three successive dipoles to negate the reading of the position monitor. With this system, the same procedures are repeated for all position monitors distributed around the main ring under the manual operation mode. The system also furnishes the online correction using the accelerator control computer by taking the beam position data into it.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.