Abstract

We report on the frequency locking of a 16 m2 ring laser to a single tooth of an optical frequency comb referenced to a hydrogen maser, obtaining a frequency stability of 1 kHz over several days. In common mode operation, where the counterpropagating laser beams run on the same longitudinal mode index, a sensitivity to rotation of 3×10(-9) relative to Earth's rotation is obtained. To test a proposal to bypass time-varying backscatter-induced readout errors in large ring laser gyroscopes, we have operated the laser on adjacent longitudinal cavity modes. The Sagnac frequency due to Earth's rotation obtained in this fashion was strongly influenced by atmospheric pressure changes because the counterpropagating beams within the cavity are affected differently by geometric cavity fluctuations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.