Abstract

In this paper, a return-stroke model based on nonuniform transmission line theory that includes nonlinear losses and corona is used for calculating close electric fields and lightning-induced voltages on an overhead line. A study is performed to identify the influence of return-stroke corona on close electric fields and line overvoltages considering different model assumptions. It is shown that the consideration of corona affects the attenuation and distortion of the return-stroke current. Close vertical electric fields predicted by the model present waveforms, peak values, and decay with distance that are in agreement with measured data. A simpler case in which the return-stroke speed is artificially set to a prescribed value by controlling the inductance and capacitance of the channel is shown to lead to results that are in agreement with the complete return-stroke model considering nonlinear losses and corona. Similar conclusions apply to popular engineering return-stroke models typically used in lightning-induced voltage calculations provided the return-stroke speed is suitably adjusted. It is also shown that lightning-induced voltages calculated with the considered model are in good agreement with experimental data.