Abstract
This research evaluated a chlorine gas–solid sodium chlorite chlorine dioxide (ClO2) generation system at the Roanoke County (Va.) Spring Hollow Water Treatment Facility and monitored concentrations of the oxidant and its by‐products within the facility and distribution system. Project objectives were to (1) document changes in ClO2, chlorite ion (ClO2–), and chlorate ion (ClO3–) concentrations throughout the facility and distribution system following raw water ClO2 pretreatment; (2) evaluate ClO2– removal by the postfilter granular activated carbon (GAC) contactors; and (3) determine distribution system ClO2 concentrations associated with odor complaints. The average raw water ClO2 dose was 0.4 mg/L, and overall ClO2– removals by GAC averaged 63% but declined markedly with increasing throughput volume. Distribution system ClO2– concentrations were generally <0.2 mg/L and decreased with increasing distance from the treatment facility; ClO3– never exceeded 0.1 mg/L. ClO2 was measured at low concentrations (0.017–0.17 mg/L) in the distribution system, and a measured concentration of 0.03 mg/L was found at the home of one customer who complained of odors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.