Abstract
The Murray law-based quantitative flow ratio (μFR) is an emerging technique that requires only 1 projection of coronary angiography with similar accuracy to quantitative flow ratio (QFR). However, it has not been validated for the evaluation of noninfarct-related artery (non-IRA) in acute myocardial infarction (AMI) settings. Therefore, our study aimed to evaluate the diagnostic accuracy of μFR and the safety of deferring non-IRA lesions with μFR >0.80 in the setting of AMI. μFR and QFR were analyzed for non-IRA lesions of patients with AMI enrolled in the FRAME-AMI trial (Fractional Flow Reserve Versus Angiography-Guided Strategy for Management of Non-Infarction Related Artery Stenosis in Patients With Acute Myocardial Infarction), consisting of fractional flow reserve (FFR)-guided percutaneous coronary intervention and angiography-guided percutaneous coronary intervention groups. The diagnostic accuracy of μFR was compared with QFR and FFR. Patients were classified by the non-IRA μFR value of 0.80 as a cutoff value. The primary outcome was a vessel-oriented composite outcome, a composite of cardiac death, non-IRA-related myocardial infarction, and non-IRA-related repeat revascularization. μFR and QFR analyses were feasible in 443 patients (552 lesions). μFR showed acceptable correlation with FFR (R=0.777; P<0.001), comparable C-index with QFR to predict FFR ≤0.80 (μFR versus QFR: 0.926 versus 0.961, P=0.070), and shorter total analysis time (mean, 32.7 versus 186.9 s; P<0.001). Non-IRA with μFR >0.80 and deferred percutaneous coronary intervention had a significantly lower risk of vessel-oriented composite outcome than non-IRA with performed percutaneous coronary intervention (3.4% versus 10.5%; hazard ratio, 0.37 [95% CI, 0.14-0.99]; P=0.048). In patients with multivessel AMI, μFR of non-IRA showed acceptable diagnostic accuracy comparable to that of QFR to predict FFR ≤0.80. Deferred non-IRA with μFR >0.80 showed a lower risk of vessel-oriented composite outcome than revascularized non-IRA. URL: https://www.clinicaltrials.gov; Unique identifier: NCT02715518.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.