Abstract

Simple SummaryWith increasing interest in precision medicine for lung cancer, cryobiopsy is expected to improve the success rate not only for histological diagnosis, but also for next-generation sequencing. Rapid on-site evaluation (ROSE) is an immediate cytological evaluation performed during bronchoscopy. However, little is known about its clinical utility during cryobiopsy. We retrospectively reviewed the data of 63 consecutive patients who underwent cryobiopsy with ROSE of touch imprint cytology (ROSE-TIC) for solid peripheral pulmonary lesions. When the results of ROSE-TIC of each patient were compared directly with the histological findings of the corresponding specimen, the sensitivity, specificity, and positive and negative predictive values were 69.8%, 90.0%, 93.8%, and 58.1%, respectively. The concordance rate was 76.2%. Therefore, we believe that ROSE-TIC, due to its high specificity and positive predictive value, may be a potential tool in deciding whether cryobiopsy sampling could be finished during bronchoscopy.Cryobiopsy enables us to obtain larger specimens than conventional forceps biopsy despite the caution regarding complications. This study aimed to evaluate the clinical utility of rapid on-site evaluation of touch imprint cytology (ROSE-TIC) during cryobiopsy of peripheral pulmonary lesions (PPLs). We retrospectively reviewed the data of consecutive patients who underwent cryobiopsy for solid PPLs between June 2020 and December 2021. ROSE-TIC was performed on the first specimen obtained via cryobiopsy and assessed using Diff-Quik staining. The results of ROSE-TIC for each patient were compared with the histological findings of the first cryobiopsy specimen. Sixty-three patients were enrolled in this study. Overall, 57 (90.5%) lesions were ≤30 mm in size and 37 (58.7%) had positive bronchus signs. The radial endobronchial ultrasound findings were located within and adjacent to the lesion in 46.0% and 54.0% of the cases, respectively. The sensitivity, specificity, and positive and negative predictive values of the ROSE results for histological findings of the corresponding specimens were 69.8%, 90.0%, 93.8%, and 58.1%, respectively. The concordance rate was 76.2%. In conclusion, ROSE-TIC, due to its high specificity and positive predictive value, may be a potential tool in deciding whether cryobiopsy sampling could be finished during bronchoscopy.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call