Abstract
To introduce an innovative procedure for portal hypertension with preliminary results and assess the technical feasibility and efficacy of portosystemic shunt creation through percutaneous transhepatic approach with its potential clinical significance. Between November 2009 and January 2011, 8 patients with complicated portal hypertension underwent percutaneous transhepatic intrahepatic portosystemic shunt (PTIPS). The severity of liver disease was Child's A (n = 2), Child's B (n = 3) and Child's C (n = 3). Under fluoroscopic guidance, portal vein (PV) was punctured with a 22-gauge Chiba needle. A 0.018-inch guidewire was advanced through the needle into PV lumen. The needle was exchanged and a 7-French sheath inserted over the wire. Then retrohepatic inferior vena cava (RIVC) or hepatic vein (HV) was punctured with a 20-gauge, 20-cm Chiba needle through sheath. Another 0.018-inch guidewire was advanced through the needle into right internal jugular vein and then snared out of body. A 0.035-inch, 260-cm-long stiff shaft wire was then introduced through the transjugular sheath and manipulated into main portal vein (MPV) and then into superior mesenteric vein (SMV). Afterward the PTIPS procedure was completed in the standard transjugular fashion. The procedure was technically successful in all patients. And effective portal decompression and free antegrade shunt flow were achieved. The mean portal pressure gradient decreased from 31.0 ± 4.3 to 18.9 ± 2.7 mm Hg before and after PTIPS creation respectively and the difference was significant statistically (P < 0.01). Among 8 patients, 1 developed hepatic coma and died after 5 days while the other 7 patients survived. The median follow-up period was 9 months (range: 2 - 20). Among 5 patients with PTIPS created for bleeding varices, no recurrent bleeding occurred during the follow-up period. For the patient with diffuse portal vein thrombosis, the clinical symptoms disappeared after PTIPS and computed tomography (CT) showed the shunt was occluded after 4 months. One patient with refractory ascites had a recurrence of abdominal distention after 2 months. There was a stenotic shunt on CT. Cure was achieved by replanting a stent in MPV. PTIPS is both safe and effective for the treatment of portal hypertension with exceptionally challenging anatomy. It is an available supplement for transjugular intrahepatic portosystemic shunt.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.