Abstract

BackgroundProper monitoring for volume overload is important to improve prognosis in peritoneal dialysis (PD) patients. The association between volume status and residual renal function (RRF) remains an unresolved issue. The aim of the present study was to evaluate the association between the edema index and survival or RRF in incident PD patients.Patients and MethodsWe identified all adults who underwent PD. The edema index was defined as the ratio of extracellular fluid to total body fluid. Participants with available data regarding survivorship or non-survivorship during the first year after PD initiation were included in the area under the receiver operating characteristic curve analysis. The cutoff value of the edema index for 1-year mortality was >0.371 in men and >0.372 in women. Participants were divided into two groups according to the cutoff value of their baseline edema indices: High (>cutoff value) and Low (≤cutoff value). Survivors during the first year after PD initiation were divided into two groups according to the initial and 1-year edema index: Non-improvement (maintenance of criteria in the initial Low group during the year) and Other (all participants except those in the Non-improvement group).ResultsIn total, 631 patients were enrolled in the present study. The cutoff value of the edema index for 1-year mortality was >0.371 in men and >0.372 in women. The respective mean initial RRF values (mL·min-1·1.73 m-2) in the Low and High groups, respectively, were 4.88 ± 4.09 and 4.21 ± 3.28 in men (P = 0.108), and 3.19 ± 2.57 and 2.98 ± 2.70 in women (P = 0.531). There were no significant differences between groups in either sex. The respective mean RRF values at 1 year after PD initiation in the Low and High groups, respectively, were 3.56 ± 4.35 and 2.73 ± 2.53 in men, and 2.80 ± 2.36 and 1.85 ± 1.51 in women. RRF at 1 year after PD initiation was higher in the Low group than in the High group (men: P = 0.027; women: P = 0.001). In men, the cumulative 5-year survival rates were 78.7% and 46.2% in the Low and High groups, respectively, whereas in women, rates were 77.2% and 58.8% in the Low and High groups, respectively. For survivors during the first year after PD initiation, the Non-improvement group was associated with a poor survival rate compared with the Other group for both sexes.ConclusionA high edema index was associated with mortality in incident PD patients at baseline and follow-up. The edema index may be used as a new marker for predicting mortality in PD patients.

Highlights

  • Peritoneal dialysis (PD) is one of the renal replacement therapies that patients with end-stage renal disease commonly undergo [1]

  • residual renal function (RRF) at 1 year after PD initiation was higher in the Low group than in the High group

  • A high edema index was associated with mortality in incident PD patients at baseline and follow-up

Read more

Summary

Introduction

Peritoneal dialysis (PD) is one of the renal replacement therapies that patients with end-stage renal disease commonly undergo [1]. Volume status is an important risk factor for morbidity and mortality in PD patients [2,3,4,5]. Previous studies have shown that volume overload is associated with higher mortality in PD patients [2,3,4,5]. Monitoring and proper intervention for volume overload are important to improve survival in PD patients. Maintenance of residual renal function (RRF) is important to improve prognosis in PD patients. The association between volume status and RRF remains an unresolved issue in PD patients. Proper monitoring for volume overload is important to improve prognosis in peritoneal dialysis (PD) patients. The association between volume status and residual renal function (RRF) remains an unresolved issue.

Objectives
Methods
Results
Conclusion