Abstract

BackgroundDespite controversial evidences, intra-aortic balloon pump (IABP) is still the most widely used temporary mechanical support device in cardiogenic shock (CS), as a bridge to recovery or to more invasive mechanical supports/heart transplantation. MethodsWe analyzed retrospectively data of all patients receiving IABP for CS from 2009 to 2018 in a referral centre for advanced heart failure and heart transplantation; we included CS following acute coronary syndrome (ACS) and other CS etiologies different from ACS. We excluded patients in which IABP was implanted as a support following cardiac surgery, non-cardiac surgery in patients with severe chronic heart failure, or in elective high risk or complicated Cath Lab procedures.We focused on in-hospital outcomes (including death, recovery, heart transplantation, LVAD) and IABP complications. Results403 patients received IABP, 303 (75.2%) following ACS and 100 (24.8%) in non-ACS CS. Non-ACS patients were younger (59 ± 18.3 vs 73.1 ± 12.6 years, p < 0.001), had lower median left ventricular ejection fraction (LVEF) (25% [18–35] vs 38% [25–45], p < 0.001). In patients with non-ACS etiologies IABP was more frequently a bridge to heart transplantation [20% (n = 20) vs 0.3% (n = 1), P < 0.001] or LVAD [4% (n = 4) vs 0.6% (n = 2), P = 0.055], while ACS patients were more frequently discharged without transplantation/LVAD [65.7% (n = 199) vs 33% (n = 33), P < 0.001]. Non-ACS patients showed higher in-hospital mortality [46% (n = 46) vs 33.9% (n = 103), P = 0.042]. Post-transplant/LVAD outcome in non-ACS subgroup was favorable (21 out of 24 patients were discharged). Serious IABP-related adverse events occurred in 21 patients (5.2%). Ischemic/hemorrhagic complications, infections and thrombocytopenia were more frequent with longer IABP stay. ConclusionsDespite therapy including percutaneous circulatory support, mortality in CS is still high. In our experience, in the clinical setting of refractory CS an IABP support represents a relatively safe circulatory support, associated with a low rate of serious complications in complex clinical scenarios.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.