Abstract

Drug-eluting stents with biodegradable polymers have been designed to improve safety and efficacy. However, drug-eluting stents with biodegradable polymers may not be a class effect, as stent strut thickness, polymer coating, and drug resorption differ between these groups of stents. Twelve months results of Scandinavian Organization for Randomized Trials With Clinical Outcome VII showed that ultrathin-strut sirolimus-eluting Orsiro stent was noninferior to the biolimus-eluting Nobori stent. The sirolimus-eluting Orsiro stent was associated with a reduced risk of definite stent thrombosis. The Scandinavian Organization for Randomized Trials With Clinical Outcome VII trial is a prospective multicenter randomized clinical trial comparing sirolimus-eluting Orsiro stent and biolimus-eluting Nobori stent in all-comers patients. The endpoint target lesion failure was a composite of cardiac death, myocardial infarction (not related to other than index lesion) and target lesion revascularization. A total of 1261 patients were randomized to treatment with sirolimus-eluting Orsiro stent and 1264 patients to biolimus-eluting Nobori stent and followed for 3 years. At 3-year the target lesion failure was comparable for sirolimus-eluting Orsiro stent (9.0%) and the biolimus-eluting Nobori stent (9.1%), (rate ratio, 0.99; 95% confidence interval, 0.77-1.29). Cardiac death (sirolimus-eluting Orsiro stent 3.0% vs. biolimus-eluting Nobori stent 2.6% [rate ratio, 1.16; 95% confidence interval, 0.73-1.86]), target lesion revascularization (sirolimus-eluting Orsiro stent 5.2% vs. biolimus-eluting Nobori stent 5.9% [rate ratio, 0.90; 95% confidence interval, 0.64-1.25]), myocardial infarction (sirolimus-eluting Orsiro stent 4.7% vs. biolimus-eluting Nobori stent 4.5% [rate ratio, 1.04; 95% confidence interval, 0.72-1.50]), and definite stent thrombosis (sirolimus-eluting Orsiro stent 1.0% vs. biolimus-eluting Nobori stent 1.7% [rate ratio, 0.59; 95% confidence interval, 0.30-1.18]) did not differ significantly between the two groups. At 3-year follow-up, target lesion failure did not differ among ultrathin-strut sirolimus-eluting Orsiro stent and biolimus-eluting Nobori stent with biodegradable polymers.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.