Abstract

To analyze the clinical outcomes after implantation of an extended range of vision intraocular lens (IOL), the Tecnis Symfony, in a routine clinical setting. Forty clinical sites in Finland, France, Germany, Norway, Spain, Sweden, and the United Kingdom. Prospective case series. The study comprised 411 patients who had bilateral implantation of the extended range of vision IOL, with intended micro-monovision in 1 group (monovision group) and intended emmetropia in the other group (non-monovision group). Visual acuity, spectacle independence, patient and surgeon satisfaction, and photic phenomena were analyzed during the 4- to 6-month follow-up. The monovision group comprised 112 patients and the non-monovision group, 299 patients. The mean decimal uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuities were 0.95, 0.81, and 0.69, respectively, 4 to 6months postoperatively. Significantly better UIVA (P=.003) and UNVA (P=.011) were found in the monovision group than in the non-monovision group. Spectacle independence was high, with 14.4% of eyes requiring reading spectacles frequently. More than 90% of patients reported no or mild halos, glare, starbursts, or other photic phenomena. Patient satisfaction scores (median) for distance, intermediate, and near vision were 9.0, 10.0, and 8.0, respectively. The satisfaction score for near vision increased to 9.0 in the monovision group. More than 91% of patients said they would recommend the same procedure to their friends and family. The extended range of vision IOL provided successful visual restoration across all distances after cataract surgery, with a minimal level of disturbing photic phenomena and high levels of patient satisfaction. Dr. Cochener is a clinical investigator for Revision Optics, Inc., Horus Vision LLC, Alcon Laboratories, Inc., Abbott Medical Optics, Inc., Théa Pharma GmbH, and Santen, Inc.; she is also a consultant to Alcon Laboratories, Inc., Abbott Medical Optics, Inc., Théa Pharma GmbH, and Santen, Inc.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.