Abstract

This study is a systematic review and meta-analysis of the clinical outcomes and pooled complication rate of femoral, tibial, and humeral fracture fixation using SIGN nails. We aimed at comparing the pooled rate of adverse events based on the country of study origin, acute versus delayed fracture fixation, and length of follow-up. We searched PubMed/MEDLINE/Cochrane databases from 2000 to 2016 for English language studies. There was substantial heterogeneity among included studies. Therefore, we used subgroup analysis of varying adverse events and removal of potential outlier studies based on the "remove one" sensitivity analysis to address the heterogeneity across studies. A funnel plot was drawn and inspected visually to assess publication bias. We reported pooled complication rates for each adverse event with 95% prediction interval. There were 14 studies with 47,169 cases across 58 different low- and middle-income countries. The average age was 33 ± 14 years, with 83% men and 17% women. Sixty percent of SIGN nails used in these 14 studies were used in femur fracture fixation, 38% in tibial shaft fractures, and the remaining 2% for humeral shaft fractures. Approximately 23% of patients had follow-up data recorded. All studies that measured clinical outcome indicated that >90% achieved full weight-bearing status, favorable range of motion (knee range of motion >90 degrees according to the SIGN database), and radiographic or clinical union depending on the specific variable(s) measured in each study. The overall complication rate was 5.2% (4.4%-6.4%). Malalignment (>5 degrees of angulation in any plane) was the most common complication (7.6%), followed by delayed/nonunion (6.9%), infection (5.9%), and hardware failure, (3.2%). Overall, the use of SIGN nails in fixing femoral, tibial, and humeral shaft fractures demonstrates good results with a high rate of return to full weight-bearing and radiographic/clinical union. The most common complications when using the SIGN nail are malalignment, delayed/nonunion, infection, and hardware failure. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.