Abstract

Anterior cruciate ligament (ACL) reconstruction has remained the gold standard for ACL injuries, especially for young individuals and athletes exposed to high level sporting activities aiming to return to their preinjury level of activity. Cortical suspensory femoral fixation is commonly performed for graft fixation to the femur in anterior cruciate ligament reconstruction using hamstring tendons. The aim of this study was to compare the clinical results of using fixed and adjustable loop cortical suspension devices in arthroscopic ACL reconstruction using the Lysholm Knee Scoring Scale after 12 months postoperatively. This study included a total of sixty patients who underwent transportal arthroscopic ACL reconstruction using a hamstring tendon autograft from November 2016 to December 2017. For femoral graft fixation, a fixed-length loop device was used in 30 patients (fixed-loop group) and an adjustable-length loop device was used in 30 patients (adjustable-loop group) randomly.For tibial graft fixation, interference screw was used for all patients. The present study shows that there was no statistically significant difference between the two groups regarding the Lysholm score with highly statistically significant difference between preoperative and postoperative Lysholm score in each group separately. Both fixed loop and adjustable loop devices in ACL reconstruction provided good clinical outcomes but without significant statistical difference between both groups from the clinical point of view postoperatively using the Lysholm score.