Abstract

The use of fibrin sealant (FS) (Tisseel™) for mesh fixation in patients undergoing laparoscopic groin hernia surgery is a well-recognised technique in Europe, but no study to date has examined effect on quality of life (QoL) on patients undergoing FS mesh fixation. A prospective study was therefore conducted to examine the effects on QoL of patients undergoing laparoscopic groin hernia surgery using FS in the United Kingdom. Between March 2007 and January 2011, all patients undergoing laparoscopic total extra preperitoneal (TEP) groin hernia repair using FS were included in the study. A validated hernia questionnaire from The Royal College of Surgeons of England supplemented by the EORTC QLQ C-30 to assess the pre- and postoperative QoL, pain scores and health outcome measures was used. All the patient's demographics, duration of surgery, size of hernia, recurrence, morbidity and hospital stay were recorded. Data from 92 patients (87 males and 5 females) with a median age of 46years (range, 19-82years) was collected for the study (response rate of 92/121, 73%). A total of 58 patients (63%) had a unilateral and 34 patients (37%) a bilateral hernia repair, of which 6 (7%) were recurrent inguinal hernia. The mean operating time for a unilateral hernia was 36min (30-62), and that for a bilateral hernia was 59min (51-83). There were no conversions to open surgery out of the 92 patients included with the recorded morbidity of 7%. There were no early recurrences. Eighty-nine patients (98%) of patients were discharged in the first 24h after surgery. There was a significant statistical difference recorded in patients visual analogue pain score (VAS 0-10) before and after surgery (P<0.0001, Mann-Whitney U test). The physical, emotional, social and health components of the questionnaire were statistically significant pre- and postoperatively (P<0.001 Mann-Whitney U test). Groin hernia TEP repair with FS fixation did not have a detrimental effect on QoL and pain scores. In addition, the low early recurrence rate provided good evidence of the mesh fixation properties of FS. FS can therefore be continued to be recommended, as an alternative fixation method in laparoscopic groin hernia surgery.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.