Abstract

Objective To analyse the cause and treatment methods for a wide range Descemet membrane detachment in phacoemulsification combined with intraocular lens implantation surgery.Methods Seven eyes of 6 cases complicated with wide range Descement membrane detachment in 825 cases (856 eyes) of phacoemulsification cataract surgery and intraocular lens implantation were involved.The Descement membrane detachment was treated by surgical suture,and (or) anterior chamber injection of C3F8,or conservative treatment.Results The surgical suture combined with anterior chamber injection of C3 F8 were performed in 5 eyes.One eye only accepted anterior chamber injection of C3F8.The conservative treatment was applied in one eye.Conclusion For Descement membrane detachment,which was caused by phacoemulsification and intraocular lens implantation,combined treatment on time is the effective method. Key words: Detachment, wide range, Descement membrane; Phacoemulsification; Treatment,combined

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.