Abstract

Purpose: To evaluate the clinical implications of the repair parameters determined experimentally in rat spinal cord and to test the feasibility of large doses per fraction or pulses in daytime high-dose-rate (HDR) or pulsed-dose-rate (PDR) brachytherapy treatment schedules as an alternative to continuous low-dose-rate (CLDR) brachytherapy. Methods and Materials: BED calculations with the incomplete repair LQ-model were performed for a primary CLDR-brachytherapy treatment of 70 Gy in 140 h or a typical boost protocol of 25 Gy in 50 h after 46-Gy conventional external beam irradiation (ERT) at 2 Gy per fraction each day. Assuming biphasic repair kinetics and a variable dose rate for the iridium-192- ( 192Ir) stepping source, the LQ-model parameters for rat spinal cord as derived in three different experimental studies were used: (a) two repair processes with an α/β ratio = 2.47 Gy and repair half-times of 0.2 h (12 min) and 2.2 h (Pop et. al.); (b) two repair processes with an α/β ratio = 2.0 Gy and repair half-times of 0.7 h (42 min) and 3.8 h (Ang et al.); and (c) two repair processes with an α/β ratio = 2.0 Gy and repair half-times of 0.25 h (15 min) and 6.4 h (Landuyt et al.). For tumor tissue, an α/β ratio of 10 Gy and a monoexponential repair half time of 0.5 h was assumed. The calculated BED values were compared with the biologic effect of a clinical reference dose of conventional ERT with 2 Gy/day and complete repair between the fractions. Subsequently, assuming a two-catheter implant similar to that used in our experimental study and with the repair parameters derived in our rat model, BED calculations were performed for alternative PDR- and HDR-brachytherapy treatment schedules, in which the irradiation was delivered only during daytime. Results: If the repair parameters of the study of Pop et al., Ang et al., or Landuyt et al. are used, for a CLDR-treatment of 70 Gy in 140 h, the calculated BED values were 117, 193, or 216 Gy sc (Gy sc was used to express the BED value for the spinal cord), respectively. These BED values correspond with total doses of conventional ERT of 65, 96, or 104 Gy. The latter two are unrealistic high values and illustrate the danger of a straightforward comparison of BED values if repair parameters are used in situations quite different from those in which they were derived. For a brachytherapy boost protocol, the impact of the different repair parameters is less, due to the fact that the percentage increase in total BED value by the brachytherapy boost is less than 50%. If a primary treatment with CLDR brachytherapy delivering 70 Gy in 140 h has to be replaced, high doses per fraction or pulses (> 1 Gy) during daytime can only be used if the overall treatment time is prolonged with 3–4 days. The dose rate during the fraction or pulse should not exceed 6 Gy/h. For a typical brachytherapy boost protocol after 46 Gy ERT, it seems to be safe to replace CLDR delivering a total dose of 25 Gy in 50 h by a total dose of 24 Gy in 4 days with HDR or PDR brachytherapy during daytime only. Total dose per day should be limited to 6 Gy, and the largest time interval as possible between each fraction or pulse should be used. Conclusion: Extrapolations based on longer repair half-times in a CLDR reference scheme may lead to the calculation of unrealistically high BED values and dangerously high doses for alternative HDR and PDR treatment schedules. Based on theoretical calculations with the IR model and using the repair parameters derived in our rat spinal cord model, it is estimated that with certain restrictions, large doses per fraction or pulses can be used during daytime schedules of HDR or PDR brachytherapy as an alternative to CLDR brachytherapy, especially for those treatment conditions in which brachytherapy is used after ERT for only less than 50% of the total dose.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.