Abstract

Polyethylene glycol (PEG) is a polymer covalently attached to proteins to improve their half-life and efficacy. We previously reported that the PEGylated granulocyte colony-stimulating factor (PEG-G-CSF) is immunogenic, which could adversely impact drug efficacy and safety in animal models. Here, we analyzed the relationship between anti-PEG antibody titers and the clinical impact of PEG-G-CSF in 19 hematological patients. A gradual decrease of anti-PEG antibody titers from baseline was observed after PEG-G-CSF administration. Of the 19 participants, 10 were assessed for noninfectious fever after the first administration of PEG-G-CSF and three experienced this reaction. The receiver operating characteristic curve revealed that the cut-off values of pretreated anti-PEG IgM and IgG titers for noninfectious fever were set at 5.0 and 96.6U/mL, respectively. All patients who experienced noninfectious fever had anti-PEG antibody titers above this cut-off value (P=.033). An enzyme-linked immunosorbent assay revealed that some anti-PEG antibodies in patients with anti-PEG antibody titers above the cut-off value reacted with the PEGylated liposome. These results indicate the reactivity of the anti-PEG antibodies to PEGylated therapeutics observed in hematologic patients and the possibility of the relationship between high titers of anti-PEG antibodies and the development of adverse events after PEG-G-CSF administration.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call