Abstract

The aim of the study was to systematically evaluate clinical outcomes of tapered fluted stems, either monoblock or modular, in revision total hip arthroplasty. PubMed, EMBASE and Web of Science and Cochrane databases were systematically searched by 2 researchers. Clinical studies reporting primarily on survival and re-revision rates, and secondarily on subsidence, dislocation, intraoperative fractures, periprosthetic fractures and infection were included. 2 investigators assessed the quality of the studies. 46 studies were included in this review, reporting on 4601 stem revisions. The pooled re-revision rate was 5.1% and long-term survival ranged from 75% to 98.5%. No differences were observed between monoblock and modular stems regarding re-revision rate, dislocation rate, periprosthetic fracture rate or infection rates. Monoblock stems exhibited more subsidence and modular stems displayed more intraoperative fractures. Satisfactory results can be obtained with the use of tapered fluted end-bearing stems. Monoblock stems offer the same clinical results as modular stems.