Abstract

In a prospective controlled study, 172 polyurethane feet of different designs were fitted to 155 amputees with trans-tibial prostheses. These were followed in respect of their durability. The amputee compliance was in general good, and 87% were satisfied with their device. After 18 months the failure rate of 20% with the CIREC spring-blade foot was significantly better than the others, but poorer craftsmanship, higher complaint rate and lower compliance rate cast some doubt on the results. The results with the conventional SACH foot constructions with polyurethane as filling and covering materials were so poor after 18 months that their use cannot be recommended in tropical areas of the developing world.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.