Abstract

BackgroundTo evaluate a semi-automatic landmark-based lesion tracking software enabling navigation between RECIST lesions in baseline and follow-up CT-scans.MethodsThe software automatically detects 44 stable anatomical landmarks in each thoraco/abdominal/pelvic CT-scan, sets up a patient specific coordinate-system and cross-links the coordinate-systems of consecutive CT-scans. Accuracy of the software was evaluated on 96 RECIST lesions (target- and non-target lesions) in baseline and follow-up CT-scans of 32 oncologic patients (64 CT-scans). Patients had to present at least one thoracic, one abdominal and one pelvic RECIST lesion. Three radiologists determined the deviation between lesions’ centre and the software’s navigation result in consensus.ResultsThe initial mean runtime of the system to synchronize baseline and follow-up examinations was 19.4 ± 1.2 seconds, with subsequent navigation to corresponding RECIST lesions facilitating in real-time. Mean vector length of the deviations between lesions’ centre and the semi-automatic navigation result was 10.2 ± 5.1 mm without a substantial systematic error in any direction. Mean deviation in the cranio-caudal dimension was 5.4 ± 4.0 mm, in the lateral dimension 5.2 ± 3.9 mm and in the ventro-dorsal dimension 5.3 ± 4.0 mm.ConclusionThe investigated software accurately and reliably navigates between lesions in consecutive CT-scans in real-time, potentially accelerating and facilitating cancer staging.

Highlights

  • To evaluate a semi-automatic landmark-based lesion tracking software enabling navigation between RECIST lesions in baseline and follow-up computed tomography (CT)-scans

  • Radiological staging of cancer patients, especially the time consuming comparison of RECIST (Response Evaluation Criteria in Solid Tumors) lesions in baseline and follow-up CT-scans became a major part of daily radiological routine

  • The software investigated in this research, is a lesion tracking device, which automatically navigates to lesions in the followup CT-examination in real time

Read more

Summary

Introduction

To evaluate a semi-automatic landmark-based lesion tracking software enabling navigation between RECIST lesions in baseline and follow-up CT-scans. Several authors addressed the ever increasing image overload, the workflow difficulties of handling huge data volumes and the time-consuming radiological reading and interpretation process [1,2] Unified standards such as the RECIST-criteria [3] for reading and reporting CTs of Previous research that engaged in solving radiological image overload has mainly been directed at improving radiologist’s user interface devices, which enable better navigation in digital data. Modern software could assist radiologists in fulfilling their task of quickly, reliably and comfortably browsing through patient examinations and comparing relevant findings in multiple examinations Existing radiological software such as in current PACS or 3D image analysis systems feature image synchronisation by picture number, by table position information or by manually assigning corresponding images. The software, does not indicate if navigated to lesions change their size in the follow-up examination, instead localizes their anatomical position while leaving the diagnosis up to the radiologist

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call