Abstract

This clinical study was designed to compare cold pulp testing (CPT), heat pulp testing (HPT) and electric pulp test (EPT) with pulse oximetry (PO), flowmetry (FM) and thermometry (TM) in terms of sensitivity and specificity. Twenty premolar teeth in need of root canal treatment were included in the study. Pulp sensibility tests (CPT, HPT and EPT) along with vitality tests (PO, FM and TM) were performed. As the gold standard, the teeth were endodontically treated and pulp vitality was determined by direct visual observation. Sensitivity, specificity and accuracy values for each test were as follows: HPT 1, 1, 100%; CPT 1, 0.818, 90%; EPT 1, 0.909, 95%; PO 1, 0.545, 75%; TM 0.111, 0.272, 20%; and FM 0.444, 0.272, 35%, respectively. The most accurate test among all was HPT. PO was the most accurate vitality test.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.