Abstract

BackgroundThe aim of this study was to investigate the usefulness of a triaxial accelerometer for the clinical assessment of standing and gait impairment in ataxic patients quantitatively. Fifty-one patients with spinocerebellar ataxia (SCA) or multiple system atrophy with predominant cerebellar ataxia (MSA-C) and 56 healthy control subjects were enrolled. The subjects, with a triaxial accelerometer on their back, were indicated to stand for 30 s in four different conditions (eyes opened or closed, and feet apart or together) and then to walk 10 m for a total of 12 times on a flat floor at their usual walking speed. In standing analysis, the degree of body sway was assessed. In gait analysis, gait velocity, cadence, step length, step regularity (auto-correlation coefficient: AC), step repeatability (cross-correlation coefficient) and the degree of body sway (The ratio of root mean square in each direction to the root mean square vector magnitude: RMSR) were evaluated.ResultsThe degree of body sway in each standing condition and all parameters in gait showed a significant difference between the patients and control subjects. The AC and RMSR values, as well as the Scale for the Assessment and Rating of Ataxia score, showed a strong correlation with disease duration.ConclusionsVarious parameters obtained by a triaxial accelerometer can be sensitive and objective markers for the assessment and follow-up of standing and gait impairment in ataxic patients.

Highlights

  • The aim of this study was to investigate the usefulness of a triaxial accelerometer for the clinical assessment of standing and gait impairment in ataxic patients quantitatively

  • Various parameters obtained by a triaxial accelerometer can be sensitive and objective markers for the assessment and follow-up of standing and gait impairment in ataxic patients

  • The postural sway with eyes closed in each stance was significantly greater than that with eyes opened in both the patients and control subjects (Fig. 1)

Read more

Summary

Introduction

The aim of this study was to investigate the usefulness of a triaxial accelerometer for the clinical assessment of standing and gait impairment in ataxic patients quantitatively. Spinocerebellar ataxia (SCA) and multiple system atrophy with predominant cerebellar ataxia (MSA-C) present mainly with gait or truncal ataxia [1, 2]. A triaxial accelerometer is a small and light device that is not stressful for the subject, and can provide various useful parameters [8–13] This device has been applied to patients with some neurodegenerative disorders such as Parkinson’s disease and Huntington’s disease [11, 14–16]. The aim of this study was to validate the usefulness of a triaxial accelerometer for the assessment of standing and gait impairment in ataxic patients

Objectives
Methods
Results

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.