Abstract

To evaluate the clinical and patient-reported outcome of all-ceramic zirconia implant supported fixed dental prostheses (FDPs) 5years after implant installation. Thirteen patients were treated with two terminally placed one-piece zirconia implants for a three-unit FDP each. The FDPs consisted of a CAD/CAM-fabricated zirconia framework over-pressed with a fluor-apatite veneering ceramic and were adhesively cemented. Survival and success were assessed by applying modified US Public Health Service (USPHS) criteria and preparation of Kaplan-Meier (KM) plots. Alpha and Bravo ratings were accepted for success (among others including small area veneer chippings and occlusal roughness), whereas Charlie ratings allowing for intra-oral correction (e.g., polishing) were accepted for survival. Furthermore, patient-reported outcome measures (PROMs) were analyzed with the help of visual analogue scales (VAS). Wilcoxon matched-pairs signed-rank test (USPHS criteria) and linear mixed models (PROMs) were used to evaluate time effects on response variables. All patients were available 61.8±1.1months after implant installation (53.6±3.1months after final prosthesis insertion). FDP survival was 100%. Significant incidence of veneer chipping (p=.0096) and occlusal roughness (p=.0019) was observed. Charlie rated extent of both phenomena resulted in a KM success estimate of 38.5% (95% CI: 14.1%-62.8%; seven FDPs with obvious roughness, three of them with extended veneer chipping). Compared with the pre-treatment assessments (30%-81% of satisfaction), all surveys at prosthetic delivery showed significantly improved VAS scores (66%-93%; p≤.038), except for speech (p=.341). Concerning function, esthetics and self-esteem, no decrease in satisfaction could be observed until the end of follow-up (90%-96%; p≥.057), whereas perception of sense (92%) and speech (95%) increased over time (p≤.030). Occurrence of technical complications did not correlate with patient satisfaction. Bi-layered FDPs made from zirconia/fluor-apatite highly satisfied patients but showed significant incidence of technical complications.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.