Abstract

The growth in bone reconstructive surgery has been unsurpassed in recent decades. However, most bone regenerative products lack any potential for delivering site-specific morphologically driven augmentation. It was therefore the purpose of this study to evaluate the histological and clinical incorporation of a novel CAD CAM allogenic block bone graft for the reconstruction of complex 3- dimensional alveolar defects. In addition the clinical outcome of dental implants subsequently placed and loaded within these grafts was assessed with up to 5 years in function. Results demonstrated that 4 of the initial 17 blocks failed (23.5%). The remaining 13 blocks plus an additional two replacement blocks were fully or partially incorporated within the recipient bone site (79%). Of the 29 implants placed within the integrated blocks, no failures occurred with up to 5 years in function, with a recorded mean marginal bone loss by implant of -0.5mm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.