Abstract

ObjectiveThe objective of this study was to explore whether chronic electrocorticographic (ECoG) data recorded by a responsive neurostimulation system could be used to assess clinical responses to antiepileptic drugs (AEDs). MethodsAntiepileptic drugs initiated and maintained for ≥3 months by patients participating in clinical trials of the RNS® System were identified. Such “AED Starts” that produced an additional ≥50% reduction in patient-reported clinical seizure frequency were categorized as clinically beneficial, and the remaining as not beneficial. Electrocorticographic features recorded by the RNS® Neurostimulator were analyzed during three periods: 3 months before the AED Start, first month after the AED Start, and the first 3 months after the AED Start. ResultsThe most commonly added medications were clobazam (n = 41), lacosamide (n = 96), levetiracetam (n = 31), and pregabalin (n = 25). Across all four medications, there were sufficient clinical data for 193 AED Starts to be included in the analyses, and 59 AED Starts were considered clinically beneficial. The proportion of AED Starts that qualified as clinically beneficial was higher for clobazam (53.7%) and levetiracetam (51.6%) than for lacosamide (18.8%) and pregabalin (12%). Across all AED Starts for which RNS ECoG detection settings were held constant, the clinically beneficial AED Starts were associated with a significantly greater reduction in the detection of epileptiform activity (p < 0.001) at 1 (n = 33) and 3 months (n = 30) compared with AED Starts that were not beneficial at 1 (n = 71) and 3 months (n = 60). Furthermore, there was a significant reduction in interictal spike rate and spectral power (1–125 Hz) associated with a clinically beneficial response to an AED Start at 1 (n = 32) and 3 months (n = 35) (p < 0.001). These reductions were not observed at either 1 (n = 59) or 3 months (n = 60) for AED Starts that were not clinically beneficial. ConclusionsSignificant quantitative changes in ECoG data recorded by the RNS System were observed in patients who experienced an additional clinical response to a new AED. While there was variability across patients in the changes observed, the results suggest that quantitative ECoG data may provide useful information when assessing whether a patient may have a favorable clinical response to an AED.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.