Abstract

Digital complete dentures (CDs) by computer-aided designing and computer-aided manufacturing (CAD-CAM) techniques (milling and three-dimensional (3-D) printing) have been evaluated clinically and provided satisfactory results. But clinical studies assessing occlusal forces by digital dentures are lacking. To compare the occlusal force parameters in complete dentures (CDs) fabricated by milling, 3-D printing and conventional techniques having 3 commonly used occlusal schemes, using computerized occlusal force analysis system (Tech-Scan III- T-Scan III). A total of 45 CDs were fabricated for 5 patients. Nine sets of CDs were made for each patient and were divided into 3 groups: Conventional CDs (CCD), Milled CDs (MCD), and 3-D printed CDs (3-DP CD). The CDs in each group were further divided into 3 sub-groups based on occlusion schemes- bilateral balanced (BBO), lingualized (LO) and mono plane (MP). Occlusal force analysis [percentage (%) of occlusal force applied on the right and left sides of the arch difference between them, centralization of forces and % of maximum occlusal/bite force] was done using computerized occlusal analysis system (T-Scan III) at the time of denture insertion. Univariate regression analysis and logistic regression analysis were performed (p< 0.05). The intergroup comparison of force distribution on right and left side in CDs fabricated by various techniques showed insignificant differences (p> 0.05) but statistically significant differences (p< 0.01) were found in right-left side force difference, maximum bite force % and centralization of forces. The maximum force difference on right and left side was observed CCD with MO (37.48 ± 1.03N) and maximum occlusal-bite force % was observed for 3-DPCD with LO (95.40 ± 1.30N). In comparison to 3-DP CD, the chances of centre of force out of ellipse (centralization of forces) was 3.36 and 2.15 times more in CCD and MCD techniques made CDs respectively. The occlusal parameters in CDs were affected by the fabrication techniques and occlusal schemes of CDs. The digital CDs retain adjusted occlusal schemes better and 3-DP CDs with BBO and LO occlusal schemes provided centralization of forces, better distribution and high maximum occlusal force % respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.