Abstract

Wearable sensors allow for the objective analysis of gait and motion both in and outside the clinical setting. However, it remains a challenge to apply such systems to highly diverse patient populations, including individuals with lower-limb amputations (LLA) that present with unique gait deviations and rehabilitation goals. This paper presents the development of a novel method using continuous gyroscope data from a single inertial sensor for person-specific classification of gait changes from a physiotherapist-led gait training session. Gyroscope data at the thigh were collected using a wearable gait analysis system for five LLA before, during, and after completing a gait training session. Data from able-bodied participants receiving no intervention were also collected. Models using dynamic time warping (DTW) and Euclidean distance in combination with the nearest neighbor classifier were applied to the gyroscope data to classify the pre- and post-training gait. The model achieved an accuracy of 98.65% ± 0.69 (Euclidean) and 98.98% ± 0.83 (DTW) on pre-training and 95.45% ± 6.20 (Euclidean) and 94.18% ± 5.77 (DTW) on post-training data across the participants whose gait changed significantly during their session. This study provides preliminary evidence that continuous angular velocity data from a single gyroscope could be used to assess changes in amputee gait. This supports future research and the development of wearable gait analysis and feedback systems that are adaptable to a broad range of mobility impairments.