Abstract

This paper summarizes results from vibration tests on floors. Classification of floors into five headings is given based on vibration characteristics. Suggested criteria and limiting values are proposed. These values are based on tests carried out on site and in laboratory conditions. It was found that the point load deflection is the best indicator for floor vibration design, when the fundamental frequency is higher than 10 Hz. It is further suggested that the deformation caused by the point load is divided into a local deflection mainly caused by soft toppings and floating floors and a global deflection of the main floor joists.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.