Abstract

Abstract The room and pillar method is usually used to extract coal from shallowly buried seams with thin bedrock. This results in a very low production efficiency and in a low degree of extraction. In recent years short-wall continuous mechanical mining has been extensively used in many situations except shallowly buried coal seams with thin bedrock. The principles governing movement of the overlying strata above the 2-2 coal seam were deduced from in-situ experience, laboratory data, calculations and computer simulations. The thicknesses of the bedrock in the Shendong Coal Field where the coal is shallowly buried are classified into 5 types: 35 m, which was done using fuzzy clustering results. A series of reasonable, relative parameters in each category have been calculated and analyzed. One proposed way to perform short-wall continuous mechanical mining in shallowly buried coal seams is given. This is significant for coal mines with similar geological conditions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.