Abstract

Ice-induced structural vibration generally decreases with an increase in structural width at the waterline. Definitions of wide/narrow ice-resistant conical structures, according to ice-induced vibration, are directly related to structure width, sea ice parameters, and clearing modes of broken ice. This paper proposes three clearing modes for broken ice against conical structures: complete clearing, temporary ice pile up, and ice pile up. In this paper, sea ice clearing modes and the formation requirements of dynamic ice force are analyzed to explore criteria determining wide/narrow ice-resistant conical structures. According to the direct measurement data of typical prototype structures, primary quantitative criterion of the ratio of a cone width at waterline (D) to sea ice thickness (h) is proposed. If the ratio is less than 30 (narrow conical structure), broken ice is completely cleared and a dynamic ice force is produced; however, if the ratio is larger than 50 (wide conical structure), the front stacking of broken ice or dynamic ice force will not occur.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call