Abstract

Surgical valve repair is a good alternative for correction of incompetent bicuspid aortic valve.To report the early and late surgical, clinical and ecochardiographic results of surgical repair of incompetent bicuspid aortic valves.Retrospective review of medical records of 18 patients aged 19 to 61 years, with incompetent bicuspid aortic valve in whom a valve repair was performed. Four patients had infectious endocarditis and 17 were in functional class I or II. Follow up ranged from 3 to 113 months after surgery.A triangular resection of the prolapsing larger cusp, which included the middle raphe, was performed in 17 cases; in 13 of these, a complementary subcommisural annuloplasty was performed. In the remaining case, with a perforation of the non-coronary cusp, a pericardial patch was implanted; this procedure was also performed in 2 other cases. In 3 cases large vegetations were removed. Postoperative transesophageal echocardiography showed no regurgitation in 11 patients (62%) and mild regurgitation in 7 (38%). There was no operative morbidity or mortality. There were no deaths during the follow-up period. In 3 patients (17%) the aortic valve was replaced with a mechanical prosthesis, 8 to 108 months after the first operation. Reoperation was not needed in 93%+/-6,4% at 1 year and 85%+/-9,5% at 5 years, these patients were all in functional class I at the end of the follow-up period. 60% had no aortic regurgitation, 20% had mild and 20% moderate aortic regurgitation on echocardiographic examination. A significant reduction of the diastolic diameter of the left ventricle was observed, but there were no significant changes in systolic diameter or shortening fraction.Surgical repair of incompetent bicuspid aortic valves has low operative morbidity and mortality and has a low risk of reoperation.

Highlights

  • Surgical valve repair is a good alternative for correction of incompetent bicuspid aortic valve

  • La ecocardiografía transesofágica intraoperatoria post reparación demostró ausencia de insuficiencia aórtica en 11 pacientes (62%) e insuficiencia leve (1+) en 7 (38%)

  • Procedimientos quirúrgicos reconstructores aórticos efectuados en 18 pacientes con válvula aórtica bicúspide insuficiente

Read more

Summary

Background

Surgical valve repair is a good alternative for correction of incompetent bicuspid aortic valve. In 3 patients (17%) the aortic valve was replaced with a mechanical prosthesis, 8 to 108 months after the first operation. Conclusions: Surgical repair of incompetent bicuspid aortic valves has low operative morbidity and mortality and has a low risk of reoperation (Rev Méd Chile 2005; 133: 279-86). Situaciones primarias de insuficiencia aórtica susceptibles de reparación serían la dilatación del anillo valvular aórtico, la válvula aórtica bicúspide, el prolapso de velo en válvula aórtica tricúspide y la perforación de velo aórtico por endocarditis infecciosa[6,9,10,11,12,13]. Recientemente comunicamos nuestra experiencia en cirugía valvular reparadora de la endocarditis infecciosa, incluyendo cierre de perforación de velos de válvulas aórticas tricúspides y bicúspides[16]. En esta oportunidad presentamos nuestra experiencia en cirugía reparadora de la válvula aórtica bicúspide insuficiente, incluyendo aquellos pacientes con lesiones endocardíticas asociadas

PACIENTES Y MÉTODO
Parche perforación
Findings
Postoperatoria p
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.