Abstract
Flow instabilities in a virtual impactor designed for bioaerosol concentration (size range about 2 to 10 μ m AD) can seriously degrade performance. When the flow in a 100 L/min circumferential slot virtual impactor (CSVI) was unstable, the transmission efficiency was 30% for 7.2 μ m AD aerosol particles, but when the instability problems were corrected, the transmission efficiency was increased to above 90%. Three-dimensional CFD simulations have been used to examine flows in two CSVIs, a nominal 10 L/min device in which the flow was stable, and the 100 L/min device in which the flow was initially unstable. From the CFD flow patterns in the 100 L/min device, the principal instability was in the minor flow region and was caused by overly rapid flow deceleration, too large of a volume, and too low of a jet velocity in that region. Changes were made to the geometry of the CSVI, and CFD was used as the diagnostic tool to determine when stable flow was achieved. Also, for the 100 L/min unit, wake effects from ...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.