Abstract

Because hemodilution decreases the oxygen-carrying capacity of blood, it was hypothesized that severe hemodilution would decrease the tolerance to alveolar hypoxia. Hemodynamics, oxygen transport, and blood lactate concentrations were compared in ten pigs with normal hematocrit (33 +/- 4%), and ten hemodiluted pigs (hematocrit 11 +/- 1%; mean +/- SD) anesthetized with ketamine-fentanyl-pancuronium during stepwise decreases in inspired oxygen fraction (FIO2; 1.0, 0.35, 0.21, 0.15, 0.10, 0.05). Median systemic oxygen delivery (DO2SY) became critical (the DO2SY value when arterial lactate exceeded 2.0 mmol.l-1) at 10.4 ml.kg-1.min-1 (range 6.9-16.1) in hemodiluted animals and at 11.8 ml.kg-1.min-1 (5.9-32.2) in animals with normal hematocrits (NS). The relationship between mixed venous oxygen saturation and arterial lactate values was less consistent and median critical mixed venous oxygen saturation was higher (P < 0.05) in the hemodiluted group (35%, range 21-64), than in animals with normal hematocrits (21%, 7-68%). In animals with normal hematocrit, decreasing FIO2 from 1.0 to 0.10 resulted in a decrease in DO2SY from 26.3 +/- 9.1 to 9.3 +/- 3.9 ml.kg-1.min-1 (P < 0.01). Cardiac output did not change, systemic oxygen extraction ratio increased from 0.23 +/- 0.08 to 0.68 +/- 0.13 (P < 0.01), and arterial lactate from 0.9 +/- 0.2 to 3.4 +/- 3.0 mmol.l-1 (P < 0.05). Cardiac venous blood flow, as measured by retrograde thermodilution, increased from 5.7 +/- 2.9 to 12.6 +/- 5.7 ml.kg-1.min-1 (P < 0.01). When FIO2 was reduced to 0.05, three animals became hypotensive and died. In the second group, hemodilution increased cardiac output and systemic oxygen extraction ratio (P < 0.01). Cardiac venous blood flow increased from 4.1 +/- 1.7 to 9.8 +/- 5.1 ml.kg-1.min-1 (P < 0.01), and cardiac venous oxygen saturation from 22 +/- 5 to 41 +/- 10% (P < 0.01). During the subsequent hypoxia, cardiac output and DO2SY were maintained until FIO2 = 0.15 (DO2SY = 10.1 +/- 3.3 ml.kg-1.min-1). Cardiac venous blood flow was then 18.5 +/- 10.7 ml.kg-1.min-1 (P < 0.01), but in spite of this, myocardial lactate production occurred. At FIO2 = 0.10 (DO2SY = 7.7 +/- 3.0 ml.kg-1.min-1), arterial lactate concentration increased to 8.5 +/- 2.3 mmol.l-1 (P < 0.01), and most animals became hypotensive. All hemodiluted animals died when FIO2 was decreased to 0.05 (P < 0.01 when compared to animals with normal hematocrit). Systemic and myocardial lactate production occurred at similar systemic oxygen delivery rates in hemodiluted and nonhemodiluted animals. Mixed venous oxygen saturation may be a less reliable indicator of inadequate oxygen delivery during hemodilution.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.