Abstract
BackgroundVancomycin (VCM) is effective in fighting Gram-positive bacteria related severe infections, and topical application of VCM powder is widely used in orthopedic surgery to prevent wound infection. However, VCM could lead to infusion rate-dependent antibody-and complement-independent anaphylaxis reaction by inducing direct release of histamine.Case presentationWe retrospectively analyzed seven cases of severe hypotension and shock during wound closure or immediately after orthopedic surgery with unidentifiable reasons. We found that these cases were all associated with local application of VCM powder during wound closure process. Two patients experienced sudden cardiac arrest. Most of the cases (6/7) with circulatory collapse were discharged without severe sequelae. While one case with application of 3 g VCM developed cardiac arrest and remained in a coma due to hypoxic-hypoxic encephalopathy. The clinical presentations and the time of the shock onset were considered to be related with a VCM induced anaphylaxis reaction. However, as this was a retrospective study, and there was no laboratory examination performed, the conclusion was made upon differential diagnosis based on clinical manifestations and the timing of the shock.ConclusionsLocal application of VCM may not be as safe as was once believed and may lead to a related anaphylaxis. As VCM induced infusion-rate dependent, non-IgE mediated anaphylaxis is characterized by delayed occurrence, severe hypotension and even circulatory collapse, surgeons and anesthesiologists should be extra vigilant during and after VCM application.
Highlights
Vancomycin (VCM) is effective in fighting Gram-positive bacteria related severe infections, and topical application of VCM powder is widely used in orthopedic surgery to prevent wound infection
As VCM induced infusion-rate dependent, non-IgE mediated anaphylaxis is characterized by delayed occurrence, severe hypotension and even circulatory collapse, surgeons and anesthesiologists should be extra vigilant during and after VCM application
We examined the intravascular volume function by performing the transthoracic echocardiography (TTE), and ruled out intraperitoneal major hemorrhage which we once encountered by examination of abdominal ultrasound and hemoglobin level; Volume status was evaluated by measuring CVP, urine output, infused fluid volume; Surgical blood loss was reviewed to exclude hemorrhage shock and hypovolemia
Summary
Local application of VCM may not be as safe as was once believed and may lead to a related anaphylaxis. As VCM induced infusion-rate dependent, non-IgE mediated anaphylaxis is characterized by delayed occurrence, severe hypotension and even circulatory collapse, surgeons and anesthesiologists should be extra vigilant during and after VCM application
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.