Abstract

Introduction: High energy fractures like gunshot-related injuries or high velocity road traffic accidents are often complex to treat and have been associated with a higher non-union rate, especially when there is extensive bone loss. Fractures with severe comminution may not heal due to bone loss and an inability to achieve adequate fracture stability. Treatment of fractures that are not amenable to plating or nailing may lead to non-unions, septic or aseptic, that need repeat surgeries. Stabilisation with external fixation is a reliable option to maintain stability and provide a suitable environment for union. Materials and methods: This retrospective study used medical records of all patients with complex mid-shaft humerus fractures, as well as their complications, that were treated with hexapod circular external fixation between January 2009 and September 2015. All the patients in this case series presented with severe humerus fractures or complications thereof which were not amenable to conventional therapy. Results: Union was achieved in ten out of the 12 cases (83.3%). Union was achieved without bone graft or any other interventions at the fracture site except implant removal where indicated. The median time in external fixation was 196 days (interquartile range: 112–228). The most common complication encountered in this series was pin-site infection. Fixation points were noted to be infected in 33% of cases at some time during the treatment period. Conclusion: This study suggests that humeral non-unions and complex humerus fractures that are not amenable to conventional fixation methods, such as intramedullary nails and plates, can successfully achieve union when treated with a hexapod circular external fixator. Level of evidence: Level 4

Highlights

  • High energy fractures like gunshot-related injuries or high velocity road traffic accidents are often complex to treat and have been associated with a higher non-union rate, especially when there is extensive bone loss

  • This retrospective study used medical records of all patients with complex mid-shaft humerus fractures, as well as their complications, that were treated with hexapod circular external fixation between January 2009 and September 2015

  • A total of four acute fractures and eight non-unions were treated in this series

Read more

Summary

Introduction

High energy fractures like gunshot-related injuries or high velocity road traffic accidents are often complex to treat and have been associated with a higher non-union rate, especially when there is extensive bone loss. Conclusion: This study suggests that humeral non-unions and complex humerus fractures that are not amenable to conventional fixation methods, such as intramedullary nails and plates, can successfully achieve union when treated with a hexapod circular external fixator. High energy fractures like gunshot-related injuries (Figure 1) or high velocity motor vehicle accidents (MVAs) are often complex to treat and have been associated with a higher non-union rate, especially when there is extensive bone loss.[1] Conventional management of these fractures would include an intramedullary nail or plate fixation to span the fracture while maintaining stability. A vital procedural step performed in this study was the radical debridement of devascularised bone ends and excision of the interposed fibrous tissue, which meant exposing the fracture site

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call