Abstract

The author describes the design and simulation of power circuits for the four Advanced Photon Source (APS) pulsed septum magnets which will be transformer type or transformer coupled to their switching circuits. Three are for synchrotron injection, extraction, and storage ring injection, operating at a 2 Hz pulse rate; one is for the Positron Accumulator Ring (PAR) operating at a 60 Hz pulse rate for both injection and extraction. The septum current pulse is approximately a half-sine-wave with a base width of approximately 1/3 ms and has a peak current, repeatable within +or-0.05%, in the transformer primary between 3.5 kA and 4.7 kA. The septum magnets have a primary inductance between 16 mu H and 23 mu H. Circuit design considerations of the switching, logic, and simulations are presented. >

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.