Abstract

To evaluate the use of spiral computed tomographic (CT) angiography in the analysis of the arteries of the circle of Willis and compare these results with magnetic resonance (MR) angiography and conventional angiography. The results in 17 patients who underwent examination were prospectively studied in a blinded fashion. The presence or absence of the arteries of the circle of Willis was determined by using maximum intensity projection reconstructions from CT angiography and MR angiography. These results were compared with results from conventional angiography. Similar sensitivities were determined for CT angiography (88.5%) and MR angiography (85.5%); however, MR angiography was found to differ significantly (P = .005) from conventional angiography. No significant differences (P > .05) were found between the two modalities and conventional angiography in the detection of the anterior, middle, or posterior cerebral arteries or the anterior communicating artery. Spiral CT angiography is highly sensitive in the detection of arterial anatomy in the circle of Willis and is a reliable alternative to MR angiography.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.