Abstract

ObjectiveTo evaluate cerebrospinal fluid dynamics, using cine phase-contrast magnetic resonance imaging (cine-PC MRI), in healthy pediatric subjects, determining the normal flow values in this population, as well as identifying differences related to age, sex, and body surface area.Materials and MethodsThis was a descriptive cross-sectional study involving 32 healthy children and adolescents, in whom the flow of cerebrospinal fluid through the cerebral aqueduct was evaluated quantitatively with cine-PC MRI. We used specialized software to analyze the images obtained with cine-PC MRI, drawing a region of interest on the aqueduct. A flow-time curve was obtained, as were automated measurements of the various parameters.ResultsThe following normal (mean) values were obtained: net flow, 1.10 ± 0.99 mL/m; stroke volume, 12.2 ± 10.1 µL/cycle; mean velocity, 0.72 ± 1.00 cm/s; peak systolic velocity, 5.28 ± 2.30 cm/s; peak diastolic velocity, 4.51 ± 1.77 cm/s. These values were not affected by age or sex. In addition, body surface area was not found to correlate significantly with mean velocity or stroke volume.ConclusionIn children and adolescents, the basic cerebrospinal fluid flow parameters, as determined by cine-PC MRI, appear to be independent of age and sex.