Abstract

IntroductionClinical application of rivaroxaban and apixaban does not require therapeutic monitoring. Commercial anti-activated factor X (anti-FXa) inhibition methods for all anti-FXa drugs are based on the same principle, so there are attempts to evaluate potential clinical application of heparin-calibrated anti-FXa assay as an alternative method for direct FXa inhibitors. We aimed to evaluate relationship between anti-FXa methods calibrated with low molecular weight heparin (LMWH) and with drug specific calibrators, and to determine whether commercial LMWH anti-FXa assay can be used to exclude the presence of clinically relevant concentrations of rivaroxaban and apixaban.Materials and methodsLow molecular weight heparin calibrated reagent (Siemens Healthineers, Marburg, Germany) was used for anti-FXa activity measurement. Innovance heparin (Siemens Healthineers, Marburg, Germany) calibrated with rivaroxaban and apixaban calibrators (Hyphen BioMed, Neuville-sur-Oise, France) was used for quantitative determination of FXa inhibitors.ResultsAnalysis showed good agreement between LMWH calibrated and rivaroxaban calibrated activity (κ = 0.76) and very good agreement with apixaban calibrated anti-Xa activity (κ = 0.82), respectively. Low molecular weight heparin anti-FXa activity cut-off values of 0.05 IU/mL and 0.1 IU/mL are suitable for excluding the presence of clinically relevant concentrations (< 30 ng/mL) of rivaroxaban and apixaban, respectively. Concentrations above 300 ng/mL exceeded upper measurement range for LMWH anti-FXa assay and cannot be determined by this method.ConclusionLow molecular weight heparin anti-FXa assay can be used in emergency clinical conditions for ruling out the presence of clinically relevant concentrations of rivaroxaban and apixaban. However, use of LMWH anti-FXa assay is not appropriate for their quantitative determination as an interchangeable method.

Highlights

  • Clinical application of rivaroxaban and apixaban does not require therapeutic monitoring

  • Low molecular weight heparin anti-factor Xa (FXa) activity cut-off values of 0.05 IU/mL and 0.1 IU/ mL are suitable for excluding the presence of clinically relevant concentrations (< 30 ng/mL) of rivaroxaban and apixaban, respectively

  • Low molecular weight heparin anti-FXa assay can be used in emergency clinical conditions for ruling out the presence of clinically relevant concentrations of rivaroxaban and apixaban

Read more

Summary

Introduction

Clinical application of rivaroxaban and apixaban does not require therapeutic monitoring. Commercial anti-activated factor X (anti-FXa) inhibition methods for all anti-FXa drugs are based on the same principle, so there are attempts to evaluate potential clinical application of heparin-calibrated anti-FXa assay as an alternative method for direct FXa inhibitors. We aimed to evaluate relationship between anti-FXa methods calibrated with low molecular weight heparin (LMWH) and with drug specific calibrators, and to determine whether commercial LMWH anti-FXa assay can be used to exclude the presence of clinically relevant concentrations of rivaroxaban and apixaban. Howev­ er, PT and APTT are not appropriate for direct FXa inhibitors, neither for quantifying drug concentra­ tion and reliable assessment of their anticoagulant effect, nor to exclude the presence of clinically rel­ evant drug concentrations in the circulation due to the high differences in sensitivities of individual commercial PT and APTT reagents [5,6,7,8,9]. The need for quantitative methods for DOACs measurement is strongly supported by increasingly published fre­ quent cases of treated patients in which extensive or fatal bleeding is described [13]

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call