Abstract

SummaryBackgroundApproximately 1–3% of the adult population in Europe are allergic to chromium (Cr). A new restriction in Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) based on the ISO 17075 standard has recently been adopted in the EU to limit Cr(VI) in consumer and occupational leather products to < 3 mg/kg.ObjectivesTo investigate the influence of storage conditions [relative humidity, temperature, ultraviolet (UV) irradiation, and duration] on Cr release, and to assess several parameters relevant for occupational exposure (repeated exposure, wear, alkaline solutions, and sequential wet and dry exposures).Material and methodsA leather of relevance for work gloves was investigated for its release of Cr(III) and Cr(VI) under these different experimental conditions.ResultsRelative humidity (water content in leather) during storage prior to Cr extraction was the single most important parameter. Cr(VI) levels could vary from non‐detectable to levels significantly exceeding the restriction limit, depending on the relative humidity. Leather contact with alkaline solution and UV irradiation during storage could increase the Cr(VI) levels in subsequent extractions.ConclusionsThe amount of Cr(VI) in leather is not an intrinsic property, but is influenced by environmental conditions of relevance for occupations and skin exposure.

Highlights

  • 1–3% of the adult population in Europe are allergic to chromium (Cr)

  • The objectives of this study were to investigate the influence of storage conditions [relative humidity (RH), temperature, ultraviolet (UV) irradiation, and duration] prior to extraction, and several parameters relevant for occupational exposure, for leather of relevance for work gloves

  • We focused on leather of relevance for work gloves

Read more

Summary

Introduction

1–3% of the adult population in Europe are allergic to chromium (Cr). A new restriction in Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) based on the ISO 17075 standard has recently been adopted in the EU to limit Cr(VI) in consumer and occupational leather products to < 3 mg/kg. To investigate the influence of storage conditions [relative humidity, temperature, ultraviolet (UV) irradiation, and duration] on Cr release, and to assess several parameters relevant for occupational exposure (repeated exposure, wear, alkaline solutions, and sequential wet and dry exposures). A leather of relevance for work gloves was investigated for its release of Cr(III) and Cr(VI) under these different experimental conditions. Relative humidity (water content in leather) during storage prior to Cr extraction was the single most important parameter. Cr(VI) levels could vary from non-detectable to levels significantly exceeding the restriction limit, depending on the relative humidity. Leather contact with alkaline solution and UV irradiation during storage could increase the Cr(VI) levels in subsequent extractions. The amount of Cr(VI) in leather is not an intrinsic property, but is influenced by environmental conditions of relevance for occupations and skin exposure

Objectives
Methods
Findings
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call